Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Search results for
All Products
Relevant Product Categories
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Fits UP15, UPS15, UP26, and UPS26
For recirculating domestic hot water - ECM permanent magnet motor - Lead free brass housing - AutoAdapt technology - Two temperature sensors - Three operating modes - 100% mode: circulator will run continuously at full speed - Temperature mode: the circulator will keep the water temperature within an automatically detected range - Auto mode: the circulator will learn, store and adapt operating times based on home hot water consumption rates - 6 foot power cord
Market Price
$9.00
Fits UP15, UPS15, UP26, and UPS26
Fits UP15, UPS15, UP26, and UPS26
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Fits UP15, UPS15, UP26, and UPS26
1 inch female IPS connections - 5 foot power cord - 1 phase - Three impellers - Integrated frequency converter - Suitable for water supply in domestic applications. Thanks to the integrated speed controller, the booster keeps a constant pressure in the pipe system. A pressure sensor monitoring changes in the water consumption, will signal to the speed controller to change the motor speed to adapt the performance to the new situation. The optional inlet pressure switch prevents the pump from operating in case of low inlet pressure. The CMBE Booster consists of these components: CME pump with integrated frequency converter, 5 way fitting with non-return valve, diaphragm tank, pressure gauge, and pressure sensor
Internally controlled and are designed for systems with variable flow rates, where the pump is internally controlled via a user interface. Speed control can reduce power consumption considerably. Eight different control modes, including constant pressure, AUTOAdapt and proportional pressure - AUTOAdapt: The AUTOAdapt function continuously adjusts the pump performance to the actual heat demand, i.e. the size of the system and the changing heat demand during the year. The function will find the setting that provides optimal comfort with minimal energy consumption. It contributes to fast, safe and easy commissioning. A magnetite resistant design, robust ceramic shaft, and stainless steel bearing plate ensure that the circulator reliably delivers the optimal system performance throughout the years at the lowest possible energy consumption.
Requires pump control box - 4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 5 gallons per minute at 350 foot head - 1 phase - 18 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
Fits UP53 and UPS53 series
Requires pump control box - 4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 5 gallons per minute at 246 foot head - 1 phase - 13 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 7 gallons per minute at 210 foot head - 1 phase - 11 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
Fits MS series motors - 1 phase - Heavy duty epoxy coated steel box with internal protective shields and a pull handle quick disconnect
Fits UP40, UPS40, UP43, and UPS43
4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 7 gallons per minute at 285 foot head - 1 phase - 15 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
Fits UP15, UPS15, UP26, and UPS26
Normally closed - With end switch - Maximum 50% Glycol - Manual open lever
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
1 inch female IPS connections - 5 foot power cord - 1 phase - Three impellers - Integrated frequency converter - Suitable for water supply in domestic applications. Thanks to the integrated speed controller, the booster keeps a constant pressure in the pipe system. A pressure sensor monitoring changes in the water consumption, will signal to the speed controller to change the motor speed to adapt the performance to the new situation. The optional inlet pressure switch prevents the pump from operating in case of low inlet pressure. The CMBE Booster consists of these components: CME pump with integrated frequency converter, 5 way fitting with non-return valve, diaphragm tank, pressure gauge, and pressure sensor
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Fits UP40, UPS40, UP43, and UPS43
Requires pump control box - 4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 7 gallons per minute at 210 foot head - 1 phase - 11 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate - Proportional pressure control - Constant pressure control - Constant curve/constant speed - Internal motor protection - Wide temperature range where the liquid temperature and the ambient temperature are independent of each other - LED control indicator
Fits UP50 and UPS50 - Four bolt flange
Fits UPS75 and UPS80 series
4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 5 gallons per minute at 430 foot head - 1 phase - 22 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
Requires pump control box - 4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 5 gallons per minute at 430 foot head - 1 phase - 22 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate - Proportional pressure control - Constant pressure control - Constant curve/constant speed - Internal motor protection - Wide temperature range where the liquid temperature and the ambient temperature are independent of each other - LED control indicator
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
Requires pump control box - 4 inch diameter pump for use with 4 inch or larger wells - 1-1/4 inch female IPS pump outlet - 10 gallons per minute at 289 foot head - 1 phase - 15 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
Requires pump control box - 4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 7 gallons per minute at 361 foot head - 1 phase - 19 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
Requires pump control box - 4 inch diameter pump for use with 4 inch or larger wells - 1 inch female IPS pump outlet - 7 gallons per minute at 285 foot head - 1 phase - 15 impellers - All stainless steel construction - Sand resistant - Resistant to aggressive water - No electronic communication is possible with this pump - Dry run protection - High efficiency pump and motor
3 inch diameter pump for use with 3 inch or larger wells - 1 inch female IPS pump outlet - 5 gallons per minute at 360 foot head - 1 phase - Dry run protection - High efficiency pump and motor - Protection against upthrust - Soft start - Over voltage and under voltage protection - Over temperature protection - High starting torque - The following are available if the pump is used with the CU-301 MkII pressure controller: Constant pressure control - Variable speed - Electronic control and communication
3 inch diameter pump for use with 3 inch or larger wells - 1 inch female IPS pump outlet - 5 gallons per minute at 320 foot head - 1 phase - Dry run protection - High efficiency pump and motor - Protection against upthrust - Soft start - Over voltage and under voltage protection - Over temperature protection - High starting torque - The following are available if the pump is used with the CU-301 MkII pressure controller: Constant pressure control - Variable speed - Electronic control and communication